Industrial Ethernet switch

$0.00

Industrial Communication

C1D2 industrial Ethernet switches are energy-efficient, durable, and robust. Our switches are suitable for use in mission-critical environments.

Industrial Communication

C1D2 industrial Ethernet switches are energy-efficient, durable, and robust. Our switches are suitable for use in mission-critical environments.

Products:

13 Total Items

  • EKI-5524MMI

    4FE+2FE SC Multi-mode Unmanaged Ethernet Switch, ATEX/C1D2, -40~75℃

    • Communicates with SCADA software via Modbus/TCP

    • Communicates with NMS (Networking management system) via SNMP

    • Port-based QoS for deterministic data transmission

    • -40~75°C operating temperature range

    • 8.4~52.8 V DC wide-range power input

    • EMS level 3 protection for extreme outdoor environments

    • IEEE 802.3az Energy Efficient Ethernet (EEE)

    • Supports redundant 12~48V DC power input and P-Fail relay

    • Loop detection

  • EKI-5526I-EI

    16FE Managed Ethernet Switch Support Multiple Industrial Protocols, -40~75℃

    • 16 ports Fast Ethernet RJ-45 (EKI-5526/I-EI)

    • Entry-Level Managed Switch

    • IXM function enables fast deployment

    • Provides PROFINET GSDML files, EtherNet/IP EDS (Electronic Data Sheet) file, AOI (Add-On Instructions) file, and FactoryTalk® View faceplate

    • Management: SNMP v1/v2c/v3, WEB, Standard MIB, Private MIB

    • Supports multiple industrial protocols such as EtherNet/IP, PROFINET and Modbus/TCP

  • EKI-5524MMI-ST

    4FE+2FE ST Multi-mode Unmanaged Ethernet Switch, ATEX/C1D2, -40~75℃

    • Communicates with SCADA software via Modbus/TCP

    • Communicates with NMS (Networking management system) via SNMP

    • Port-based QoS for deterministic data transmission

    • -40~75°C operating temperature range (EKI-5524SSI/SSI-ST,EKI-5524MMI/MMI-ST only)

    • 12 ~48 V DC (8.4 ~52.8 V DC ) wide-range power input

    • EMS level 3 protection for extreme outdoor environments

    • IEEE 802.3az Energy Efficient Ethernet (EEE)

    • Supports redundant 12~48V DC power input and P-Fail relay

    • Loop detection

  • EKI-5526I-MB

    16FE Managed Ethernet Switch support Modbus/TCP, -40~75℃

    • 16 ports Fast Ethernet RJ-45 (EKI-5526/I-MB)

    • Entry-Level Managed Switch

    • IXM function enables fast deployment

    • Management: SNMP v1/v2c/v3, WEB, Standard MIB, Private MIB

  • EKI-5526I-MB

    16FE Managed Ethernet Switch support Modbus/TCP, -40~75℃

    • 16 ports Fast Ethernet RJ-45 (EKI-5526/I-MB)

    • Entry-Level Managed Switch

    • IXM function enables fast deployment

    • Management: SNMP v1/v2c/v3, WEB, Standard MIB, Private MIB

  • EKI-5524SSI

    4FE+2FE SC Single-mode Unmanaged Ethernet Switch, ATEX/C1D2, -40~75℃

    • Communicates with SCADA software via Modbus/TCP

    • Communicates with NMS (Networking management system) via SNMP

    • Port-based QoS for deterministic data transmission

    • -40~75°C operating temperature range (EKI-5524SSI/SSI-ST,EKI-5524MMI/MMI-ST only)

    • 8.4~52.8 V DC wide-range power input

    • EMS level 3 protection for extreme outdoor environments

    • IEEE 802.3az Energy Efficient Ethernet (EEE)

    • Supports redundant 12~48V DC power input and P-Fail relay

    • Loop detection

  • EKI-5526I-PN

    16FE Managed Ethernet Switch support PROFINET, -40~75℃

    • 16 ports Fast Ethernet RJ-45 (EKI-5526/I-PN)

    • Entry-Level Managed Switch

    • IXM function enables fast deployment

    • Provides GSDML files

    • Management: SNMP v1/v2c/v3, WEB, Standard MIB, Private MIB

    • Supports Media Redundancy Protocol (Media Redundancy Client)

  • EKI-5524SSI-ST

    4FE+2FE ST Single-mode Unmanaged Ethernet Switch, ATEX/C1D2, -40~75℃

    • Communicates with SCADA software via Modbus/TCP

    • Communicates with NMS (Networking management system) via SNMP

    • Port-based QoS for deterministic data transmission

    • -40~75°C operating temperature range (EKI-5524SSI/SSI-ST,EKI-5524MMI/MMI-ST only)

    • 12 ~48 V DC (8.4 ~52.8 V DC ) wide-range power input

    • EMS level 3 protection for extreme outdoor environments

    • IEEE 802.3az Energy Efficient Ethernet (EEE)

    • Supports redundant 12~48V DC power input and P-Fail relay

    • Loop detection

  • EKI-5528-PNMA

    8FE Managed Ethernet Switch support PROFINET MRP Manager

    • 8 ports Fast Ethernet RJ-45

    • Entry-Level Managed Switch

    • IXM function enables fast deployment

    • Provides GSDML files

    • Management: SNMP v1/v2c/v3, WEB, Standard MIB, Private MIB

    • Supports Media Redundancy Protocol (MRP Manager)

  • EKI-5525I

    5FE Unmanaged Ethernet Switch, ATEX/C1D2, -40~75℃

    • Communicates with SCADA software via Modbus/TCP

    • Communicates with NMS (Networking management system) via SNMP

    • Port-based QoS for deterministic data transmission

    • 40~75°C operating temperature range

    • 8.4~52.8 V DC wide-range power input

    • EMS level 3 protection for extreme outdoor environments

    • IEEE 802.3az Energy Efficient Ethernet (EEE)

    • Supports redundant 12~48V DC power input and P-Fail relay

    • Loop detection

  • EKI-5528I-EI

    8FE Managed Ethernet Switch Support Multiple Industrial Protocols,-40~75℃

    • 8 ports Fast Ethernet RJ-45 (EKI-5528/I-EI)

    • Entry-Level Managed Switch

    • IXM function enables fast deployment

    • Provides PROFINET GSDML files, EtherNet/IP EDS (Electronic Data Sheet) file, AOI (Add-On Instructions) file, and FactoryTalk® View faceplate

    • Management: SNMP v1/v2c/v3, WEB, Standard MIB, Private MIB

    • Supports multiple industrial protocols such as EtherNet/IP, PROFINET and Modbus/TCP

  • EKI-2741FPI

    1GE PoE, SFP Injector ,IEEE802.3af/at, 24~48VDC, -40~75℃

    • Supports multi-rate for SFP slot

    • IEEE 802.3af/at compliant

    • Power input 24-48 VDC, supply 30W per port

    • Provides slim size and DIN-rail/Wall mount with IP31 metal mechanism

    • Supports operating temperatures from -40 to 75°C

  • EKI-5525SI

    4FE+1FE SC Single-mode Unmanaged Ethernet Switch, ATEX/C1D2, -40~75℃

    • Communicates with SCADA software via Modbus/TCP

    • Communicates with NMS (Networking management system) via SNMP

    • Port-based QoS for deterministic data transmission

    • -40~75°C operating temperature range (EKI-5525SI/SI-ST,EKI-5525MI/MI-ST only)

    • 8.4~52.8 V DC wide-range power input

    • EMS level 3 protection for extreme outdoor environments

    • IEEE 802.3az Energy Efficient Ethernet (EEE)

    • Supports redundant 12~48V DC power input and P-Fail relay

    • Loop detection