These are switching technology devices with microcontroller, which best optimizes the charging and discharging time of the accumulator, avoiding deep discharge of the batteries. The switching time on the load is zero; switching between the input and the battery is immediate. All DC-UPSs are protected against reverse polarity, short circuit, overload and the output overvoltage.

These are switching technology devices with microcontroller, which best optimizes the charging and discharging time of the accumulator, avoiding deep discharge of the batteries. The switching time on the load is zero; switching between the input and the battery is immediate. All DC-UPSs are protected against reverse polarity, short circuit, overload and the output overvoltage.

Key Features

  • Output voltage 12, 24, 48Vdc, even in the absence of power supply

  • Fault signaling via relay contact, blink code, and Modbus RTU and TCP/IP protocols

  • Output power: 60W, 120W, 240W, 250W, 280W, 500W, 600W

  • DC-UPS and battery self-diagnosis: high voltage; sulfated battery; reverse connection; possible shorted element; short circuit protection

  • Accessories: battery temperature sensor, external display, PC and Modbus connection cables

  • Ultracompact design

  • Output current 2.5A ÷ 25A, even in the absence of AC mains

  • Automated power sharing of available power between load and battery charging

  • Power boost, up to 3 times the rated current available. Ability to handle high current surges

  • "Main or back-up" and "battery failure/discharge" signaling relays with galvanically isolated output contacts

  • Fast battery recharging for cyclic applications

  • Temperature operation range -40 ÷ 70°C

Products

Power Supplies for Building Automation 12Vdc

    • Input: Single-phase 115 – 277 Vac

    • Output Load: power supply 12 Vdc; 3 A

    • Output Battery: charging 12 Vdc; 3 A

    • Suited for the following battery types: Open Lead Acid, Sealed

    • Lead Acid, Lead Gel, Li-Ion and Ni-Cd

    • Automatic diagnostic of battery status. Charging curve IUoU,

    • constant voltage and constant current Battery Life Test function

    • (Battery Care)

    • Switching technology, output voltage 10-14.4Vdc Three charging

    • levels: Boost, Float and Recovery

    • Protected against short circuit and inverted polarity

    • Signal output (contact free) for discharged or damaged battery

    • Signal output (contact free) for mains or Back-UP

    • Protection degree IP20 - DIN rail; Space savin

    • Input: Single-phase 115 – 277 Vac

    • Output Load: power supply 12 Vdc; 6 A

    • Output Battery: charging 12 Vdc; 6 A

    • Suited for the following battery types: Open Lead Acid, Sealed

    • Lead Acid, Lead Gel, Li-Ion and Ni-Cd

    • Automatic diagnostic of battery status. Charging curve IUoU,

    • constant voltage and constant current Battery Life Test function

    • (Battery Care)

    • Switching technology, output voltage 10-14.4Vdc Three charging

    • levels: Boost, Float and Recovery

    • Protected against short circuit and inverted polarity

    • Signal output (contact free) for discharged or damaged battery

    • Signal output (contact free) for mains or Back-UP

    • Protection degree IP20 - DIN rail; Space saving

    • Input: Single-phase 115 – 277 Vac

    • Output Load: power supply 12 Vdc; 10 A

    • Output Battery: charging 12 Vdc; 10 A

    • Suited for the following battery types: Open Lead Acid, Sealed

    • Lead Acid, Lead Gel, Li-Ion and Ni-Cd

    • Automatic diagnostic of battery status. Charging curve IUoU,

    • constant voltage and constant current Battery Life Test function

    • (Battery Care)

    • Switching technology, output voltage 10-14.4Vdc Three charging

    • levels: Boost, Float and Recovery

    • Protected against short circuit and inverted polarity

    • Signal output (contact free) for discharged or damaged battery

    • Signal output (contact free) for mains or Back-UP

    • Protection degree IP20 - DIN rail; Space saving

    • Input: Single-phase 115 – 277 Vac; 550W

    • Output Load: power supply 12 Vdc; 35 A

    • Output Battery: charging 12 Vdc; 35 A

    • Suited for the following battery types: Open Lead Acid, Sealed

    • Lead Acid, Lead Gel, Li-Ion and Ni-Cd, Li-Ion

    • Automatic diagnostic of battery status. Charging curve IUoU,

    • constant voltage and constant current Battery Life Test function

    • (Battery Care)

    • Switching technology, output voltage 10-14.4 Vdc

    • Three charging levels: Boost, Float and Recovery

    • Protected against short circuit and inverted polarity

    • Signal output (contact free) for discharged or damaged battery

    • Signal output (contact free) for mains or Back-UP

    • Protection degree IP20 - DIN rail; Space saving

Power Supplies for Building Automation 24Vdc

    • Input: Single-phase 115 – 277 Vac

    • Output Load: power supply 24 Vdc; 3 A

    • Output Battery: charging 24 Vdc; 3 A

    • Suited for the following battery types: Open Lead Acid, Sealed

    • Lead Acid, Lead Gel, Li-Ion and Ni-Cd

    • Automatic diagnostic of battery status. Charging curve IUoU,

    • constant voltage and constant current Battery Life Test function

    • (Battery Care)

    • Switching technology, output voltage 22-28.8Vdc Three charging

    • levels: Boost, Float and Recovery

    • Protected against short circuit and inverted polarity

    • Signal output (contact free) for discharged or damaged battery

    • Signal output (contact free) for mains or Back-UP

    • Input: Single-phase 115 – 277 Vac

    • Output Load: power supply 24 Vdc; 5 A

    • Output Battery: charging 24 Vdc; 5 A

    • Suited for the following battery types: Open Lead Acid, Sealed

    • Lead Acid, Lead Gel, Li-Ion and Ni-Cd

    • Automatic diagnostic of battery status. Charging curve IUoU,

    • constant voltage and constant current Battery Life Test function

    • (Battery Care)

    • Switching technology, output voltage 22-28.8Vdc Three charging

    • levels: Boost, Float and Recovery

    • Protected against short circuit and inverted polarity

    • Signal output (contact free) for discharged or damaged battery

    • Signal output (contact free) for mains or Back-UP

    • Output Load: power supply 24 Vdc; 10 A

    • Output Battery: charging 24 Vdc; 10 A

    • Suited for the following battery types: Open Lead Acid, Sealed

    • Lead Acid, Lead Gel, Li-Ion and Ni-Cd

    • Automatic diagnostic of battery status. Charging curve IUoU,

    • constant voltage and constant current Battery Life Test function

    • (Battery Care)

    • Switching technology, output voltage 22-28.8Vdc Five charging

    • levels: Boost, Bulk, Absorption, Float and Recovery

    • Protected against short circuit and inverted polarity

    • Signal output (contact free) for discharged or dama

    • Input: Single-phase 115 – 230 Vac (277 Vac operational)

    • Output Load: power supply 24 Vdc; 20A

    • Power boost: 25A (4 minutes)

    • Output Battery: charging 24 Vdc; 20A

    • Suited for the following battery types: Open Lead Acid,

    • Sealed Lead Acid, lead Gel and Ni-Cd, Ni-MH, Li-Ion

    • Automatic diagnostic of battery status.

    • Charging curve IUoU, constant voltage and constant

    • current Battery Life Test function (Battery Care)

    • Switching technology Four charging levels: Recovery,

    • Bulk, Absorption, Boost, and Float

    • Protected against short circuit and inverted Batt. polarity

    • Signal output (contact free) for discharged or damaged

    • battery

    • Signal output (contact free) for Mains or Back-UP

    • Modbus RTU for all parameter, Battery and System

    • Protection degree IP20 - DIN rail; Space saving

All in one 48Vdc

    • Input: Single-phase 115 – 277 Vac

    • Output Load: power supply 48 Vdc; 5 A

    • Output Battery: charging 48 Vdc; 5 A

    • Suited for the following battery types: Open Lead Acid, Sealed

    • Lead Acid, Lead Gel, Li-Ion and Ni-Cd

    • Automatic diagnostic of battery status. Charging curve IUoU,

    • constant voltage and constant current Battery Life Test function

    • (Battery Care)

    • Switching technology, output voltage 44 - 57.6Vdc Five charging

    • levels: Boost, Bulk, Absorption, Float and Recovery

    • Protected against short circuit and inverted polarity

    • Signal output (contact free) for discharged or damaged battery

    • Signal output (contact free) for mains or Back-UP

    • Protection degree IP20 - DIN rail; Space saving

    • Input: Single-phase 115 – 277 Vac; 600W

    • Output Load: power supply 48 Vdc; 12.5 A

    • Output Battery: charging 48 Vdc; 12.5 A

    • Suited for the following battery types: Open Lead Acid,

    • Sealed Lead Acid, lead Gel and Ni-Cd, Ni-MH, Li-Ion

    • Automatic diagnostic of battery status.

    • Charging curve IUoU, constant voltage and constant

    • current Battery Life Test function (Battery Care)

    • Switching technology Four charging levels: Recovery,

    • Bulk, Absorption, Boost, and Float

    • Protected against short circuit and inverted Batt. polarity

    • Signal output (contact free) for discharged or damaged

    • battery

    • Signal output (contact free) for Mains or Back-UP

    • Modbus RTU for all parameter, Battery and System

    • Protection degree IP20 - DIN rail; Space saving

All in one 12-24Vdc

    • Input: Single-phase 100 - 240 - 277 Vac

    • Output Selectable Load: 12 Vdc 15A; 24 Vdc 10A

    • Output Battery charging: 12 Vdc 15A; 24 Vdc 10A

    • Suited for the following battery types: Open Lead Acid,

    • Sealed Lead Acid, Lead Gel, Lead Crystal, Ni-Cd, Ni-MH, Li-Ion

    • Automatic diagnostic of battery status. Charging curve IUoU,

    • constant voltage and constant current Battery Life Test

    • function (Battery Care)

    • Four charging levels: Boost, Absorption, Float, Recovery

    • Protected against short circuit and inverted polarity

    • Signal output (contact free) for discharged or damaged

    • battery

    • Signal output (contact free) for mains or Back-UP

    • Modbus RTU for all parameter battery and system

    • Protection degree IP20

    • DIN rail; Space saving

  • nput: Single-phase 100 – 240 - 277 Vac / 140 – 340 Vdc

    ▪ Output Selectable Load: 12 Vdc 10A; 24 Vdc 10A

    ▪ Two output: 1 Continuous, 1 Dynamic: On/Off by Modbus

    ▪ Output Battery charging: 12 Vdc 10A; 24 Vdc 10A

    ▪ Two load outputs: one static; one dynamic for: On/Off, Dimmer

    (LED, DC brush motors), Fuse Breaker, PC shutdown and more

    ▪ Modbus RTU for Monitoring, Configuration, History and Alarms.

    ▪ ADELBus: integrated monitoring and control of ADELSystem

    devices such as MRF10x e-Fuses and display.

    ▪ Suitable for the following battery types: Open Lead Acid, Sealed

    Lead Acid (AGM/VRLA), lead Gel, Li-Ion and NiCd/NiMH

    ▪ Battery Care: Automatic diagnostic of battery state-of-charge

    (SoC) and state-of-health (SoH).

    ▪ Charging curve IUoU, constant voltage and constant current.

    ▪ Five charging levels: Recovery, Boost, Absorption, Float (Forced

    trickle / Forced float / Auto float-trickle), and Refresh

    ▪ Battery purification for battery reinvigoration

    ▪ Protected against short circuit and reversed polarity

    ▪ Signal output (contact free) for: discharged or damaged battery,

    Mains or Back-up, rectifier failure

    ▪ Protection degree IP20 - DIN rail; Space saving