TDR-480

$0.00

480W Three Phase Industrial DIN RAIL with PFC Function

TDR-480 series:

  • TDR-480-24

  • TDR-480-48

Model:

480W Three Phase Industrial DIN RAIL with PFC Function

TDR-480 series:

  • TDR-480-24

  • TDR-480-48

Wattage : 240W~960W

Features:

  • Metal case, slim size

  • 3∅, 340~550VAC input

  • High efficiency up to 94.5%

  • Built-in active PFC function

  • Assemble on industrial rail TS-35 / 7.5 or 15

  • Built-in DC OK relay contact

Power Supply Specification Table - TDR-480

Specification

MODEL TDR-480-24 TDR-480-48
OUTPUT DC VOLTAGE 24V 48V
RATED CURRENT 20A 10A
CURRENT RANGE 0 ~ 20A 0 ~ 10A
RATED POWER 480W 480W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 24 ~ 28V 48 ~ 55V
VOLTAGE TOLERANCE Note.3 ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0%
SETUP, RISE TIME 1200ms, 60ms/400VAC      800ms, 60ms/500VAC at full load
HOLD UP TIME (Typ.) 20ms / 400VAC      20ms / 500VAC at full load
INPUT VOLTAGE RANGE Note.4 Three-Phase 340 ~ 550VAC (Dual phase operation possible) 480 ~ 780VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF≥0.9/400VAC      PF≥0.88/500VAC at full load
EFFICIENCY (Typ.) 92.5% 93%
AC CURRENT (Typ.) 0.85A/400VAC      0.7A/500VAC
INRUSH CURRENT (Typ.) COLD START 50A
LEAKAGE CURRENT <3.5mA / 530VAC
PROTECTION OVERLOAD 105 ~ 130% rated output power
Protection type : Constant current limiting, unit will shut down after 3 sec., re-power on to recover
OVER VOLTAGE 29 ~ 33V 56 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT WORKING TEMP. Note.5 -30 ~ +70°C (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85°C, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/°C (0 ~ 50°C)
VIBRATION Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY &
EMC
(Note 4)
SAFETY STANDARDS UL508, IEC62368-1, UL62368-1, AS/NZS 62368.1, BIS IS13252(Part1)(only for 24V), EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE I/P-O/P:3KVAC    I/P-FG:2KVAC    O/P-FG:0.5KVAC    O/P-DC OK(optional):0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25°C / 70% RH
EMC EMISSION
Parameter Standard Test Level / Note
Conducted BS EN/EN55032(CISPR32) / BS EN/EN61204-3 Class B
Radiated BS EN/EN55032(CISPR32) / BS EN/EN61204-3 Class B
Harmonic Current BS EN/EN61000-3-2 Class A
Voltage Flicker BS EN/EN61000-3-3 -----
EMC IMMUNITY
BS EN/EN55035 , BS EN/EN61204-3
Parameter Standard Test Level / Note
ESD BS EN/EN61000-4-2 Level 4, 15KV air ; Level 4, 8KV contact
Radiated Field BS EN/EN61000-4-3 Level 3
EFT / Burst BS EN/EN61000-4-4 Level 3
Surge BS EN/EN61000-4-5 Level 4, 2KV/Line-Line, 4KV/Line-Earth
Conducted BS EN/EN61000-4-6 Level 3
Magnetic Field BS EN/EN61000-4-8 Level 4
Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS MTBF 1174.0K hrs min.    Telcordia SR-332(Bellcore) ; 108.3K hrs min.    MIL-HDBK-217F (25°C)
DIMENSION 85.5*125.2*128.5mm (W*H*D)
PACKING 1.51Kg ; 8pcs/13Kg/1.16CUFT