TDR-960

$0.00

960W Three Phase Industrial DIN RAIL with PFC Function

TDR-960 series:

  • TDR-960-24

  • TDR-960-48

Model:

960W Three Phase Industrial DIN RAIL with PFC Function

TDR-960 series:

  • TDR-960-24

  • TDR-960-48

Wattage : 240W~960W

Features:

  • Metal case, slim size

  • 3∅, 340~550VAC input

  • High efficiency up to 94.5%

  • Built-in active PFC function

  • Assemble on industrial rail TS-35 / 7.5 or 15

  • Built-in DC OK relay contact

Power Supply Specification Table - TDR-960

Specification

MODEL TDR-960-24 TDR-960-48
OUTPUT DC VOLTAGE 24V 48V
RATED CURRENT 40A 20A
CURRENT RANGE 0 ~ 40A 0 ~ 20A
RATED POWER 960W 960W
RIPPLE & NOISE (max.) Note.2 180mVp-p 250mVp-p
VOLTAGE ADJ. RANGE 24 ~ 28V 48 ~ 55V
VOLTAGE TOLERANCE Note.3 ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0%
SETUP, RISE TIME 1000ms, 100ms/400VAC      800ms, 100ms/500VAC at full load
HOLD UP TIME (Typ.) 12ms / 400VAC      14ms / 500VAC at full load
INPUT VOLTAGE RANGE Note.4 Three-Phase 340 ~ 550VAC (Dual phase operation possible) 480 ~ 780VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF≥0.88/400VAC      PF≥0.86/500VAC at full load
EFFICIENCY (Typ.) 94% 94.5%
AC CURRENT (Typ.) 2A/400VAC      1.4A/500VAC
INRUSH CURRENT (Typ.) COLD START 60A
LEAKAGE CURRENT <3.5mA / 530VAC
PROTECTION OVERLOAD 105 ~ 130% rated output power
Protection type : Constant current limiting, unit will shut down after 3 sec., re-power on to recover
OVER VOLTAGE 29 ~ 33V 56 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION DC OK RELAY CONTACT RATINGS (max.) 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load
CURRENT SHARING Please refer to function manual
ENVIRONMENT WORKING TEMP. Note.5 -30 ~ +70°C (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85°C, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.03%/°C (0 ~ 50°C)
VIBRATION Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY &
EMC
(Note 6)
SAFETY STANDARDS UL508, AS/NZS62368.1, BIS IS13252(Part1) (only for 24V), EAC TP TC 004 approved, IEC62368-1 CB approved by SIQ; Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE I/P-O/P:3KVAC    I/P-FG:2KVAC    O/P-FG:0.5KVAC    O/P-DC OK:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25°C / 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN61204-3, heavy industry level, EAC TP TC 020
OTHERS MTBF 647.1K hrs min.    Telcordia SR-332 (Bellcore) ; 59.5K hrs min.    MIL-HDBK-217F (25°C)
DIMENSION 110*125.2*150mm (W*H*D)