Introduction
The MGate 5121 is an industrial Ethernet gateway for converting CANopen, J1939, and proprietary CAN (CAN 2.0A/B) to Modbus TCP network communications. To integrate existing CAN–based devices onto a Modbus TCP network, use the MGate 5121 as a CAN Master to collect data and exchange data with the Modbus TCP host. All models are protected by a rugged and compact metal housing and are DIN-rail mountable. The rugged design is suitable for industrial applications such as factory automation, process automation, and power applications.
Easy Configuration
The MGate 5121 gateways are provided with a web console to make configuration easy without having to install an extra utility. In addition, HTTPS encryption of communication ensures higher network security.
In most data-acquisition applications, configuration of CANopen devices can be time-consuming and increase costs. The MGate 5121 gateways provide EDS file import function and user can auto scan the CANopen devices to help complete the settings quickly. The MGate gateways provide software-configurable termination resistor settings for CANbus to reduce efforts by eliminating the need to open the chassis.
Easy Troubleshooting
The MGate 5121 gateways provide a variety of maintenance functions to reduce troubleshooting time and cost, including LED indicators, protocol diagnostics, traffic monitor, and tag view. These tools help you capture and check data to easily identify the root cause of issues, especially during the installation stage. The MGate gateways also come with status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a CAN device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators. The fault protection function executes actions pre-defined by the user when a host gets disconnected to prevent the end devices from going offline for long periods of time.
Features and Benefits
Simultaneous protocol conversions from CANopen, J1939, and proprietary CAN (CAN 2.0A/B) to Modbus TCP and SNMP
Supports Modbus TCP Server (Slave) and SNMP Agent
Supports CANopen master, J1939, and proprietary CAN (CAN 2.0A/B)
Flexible deployment with Ethernet cascading and dual subnet
Embedded traffic monitoring/diagnostic information for easy troubleshooting
Easy device configuration via a web-based console
microSD card for configuration backup/duplication
Supports dual redundant DC power inputs and 1 relay output
CAN port with 2-kV isolation protection
Compliance with IEC 62443-4-2 Security Level 2 requirements
-40 to 75°C wide operating temperature models available
Available Models (2)
MGate 5121
MGate 5121-T